Please use this identifier to cite or link to this item: http://drsr.daiict.ac.in//handle/123456789/1032
Title: Capacitive Electrode for Bio-Medical Applications
Authors: Parekh, Rutu
Agrawal, Yash
Purohit, Shubham
Keywords: magnetic resonance imaging(MRI)
Computed tomography (CT) Scanners
Ultrasound imaging
Band-pass filter
Notch filter
Issue Date: 2021
Citation: Purohit, Shubham (2021). Capacitive Electrode for Bio-Medical Applications. Dhirubhai Ambani Institute of Information and Communication Technology. ix, 35 p. (Acc.No: T00968)
Abstract: In recent years, advancements in medical and healthcare-based embedded systems have increased rapidly. Such systems include magnetic resonance imaging (MRI), computed tomography (CT) scanners, ultrasound imaging, digital flow sensors, electrocardiogram (ECG), and electroencephalogram (EEG) monitoring appliances. With the advancements in VLSI and e-technology, the overall chip size has reduced, and eventually, the functionality of the system has increased manifolds. In biomedical applications, electrodes are widely incorporated to sense the electrical activity of the human body. One of the vital use of the electrodes is to sense the ECG signal of the patient’s body for monitoring the activity of the heart. For this purpose, electrode equivalent model, electrode-skin interface, several different electrodes used in biomedical applications like surface electrodes, microelectrodes, needle electrodes have been studied. Apart from this Dry flexible electrodes using PDMS substrate and wet electrodes like Ag/Agcl electrodes are investigated, an effective capacitive electrode-based single-lead ECG system has been explored which contains pre-amplification circuitry, Band-pass filter, and notch filter. Each of these circuits is designed and the performance of an overall system is accessed using two different versions of theWilson central terminal ECG database. The proposed system has a very good correlation with the original ECG signal database. The frequency response of the band-pass filter and notch filter is computed and drawn to derive their cutoff frequencies. The presented capacitivebased electrode is proposed to be an optimal electrode for ECG signal detections in upcoming biomedical applications.
URI: http://drsr.daiict.ac.in//handle/123456789/1032
Appears in Collections:M Tech Dissertations

Files in This Item:
File Description SizeFormat 
201911041_Shubham Purohit_M.Tech. Final Thesis - YASH AGRAWAL.pdf
  Restricted Access
1.56 MBAdobe PDFView/Open Request a copy


Items in DSpace are protected by copyright, with all rights reserved, unless otherwise indicated.