Publication: Ultra-low power digital front-end for single lead ECG acquisition integrated with a time-to-digital converter
dc.contributor.affiliation | DA-IICT, Gandhinagar | |
dc.contributor.author | Mishra, Biswajit | |
dc.contributor.author | Thakkar, Sanket | |
dc.contributor.author | Jain, Nupur | |
dc.contributor.author | Mishra, Biswajit | |
dc.contributor.author | Mishra, Biswajit | |
dc.contributor.author | Mishra, Biswajit | |
dc.contributor.author | Mishra, Biswajit | |
dc.contributor.author | Mishra, Biswajit | |
dc.contributor.researcher | Thakkar, Sanket (201611046) | |
dc.contributor.researcher | Jain, Nupur (201221008) | |
dc.date.accessioned | 2025-08-01T13:09:37Z | |
dc.date.issued | 16-07-2019 | |
dc.description.abstract | A low power single lead electrocardiogram front-end acquisition system in 0.18 ?m CMOS operating at 0.5 V is presented here. The analogue blocks in low noise amplifier (LNA), filters and passive elements that perform amplification and DC offset cancellation are replaced by a moving average voltage to time converter (MA-VTC) to get amplification and anti-aliasing in the time domain. A digital feedback algorithm is used to cancel out the DC offset. The front-end structure is designed in the sub-threshold region of MOS to reduce the power consumption in the circuit. The proposed architecture consumes 50 nW of power with a gain of 670 ?s/V. The output of the front-end is fed to an all digital time-to-digital converter (TDC) that operates in the near threshold region with a resolution of 586.4 ps and 32.5 ?W power consumption. | |
dc.format.extent | 453-460 | |
dc.identifier.citation | Mishra, Biswajit, Sanket Thakkar and Nupur Jain"Ultra-low power digital front-end for single lead ECG acquisition integrated with a time-to-digital converter," IET Computers and Digital Techniques, Institution of Engineering and Technology, vol. 13, issue. 6, ISSN: 17518601, pp. 453-460, 2019, doi: 10.1049/iet-cdt.2019.0027. | |
dc.identifier.doi | 10.1049/iet-cdt.2019.0027 | |
dc.identifier.issn | 1751-861X | |
dc.identifier.scopus | 2-s2.0-85074286449 | |
dc.identifier.uri | https://ir.daiict.ac.in/handle/dau.ir/2074 | |
dc.identifier.wos | WOS:000493114300005 | |
dc.language.iso | en | |
dc.publisher | IET | |
dc.relation.ispartofseries | Vol. 13; No. 6 | |
dc.source | IET Computers and Digital Techniques, Institution of Engineering and Technology | |
dc.source.uri | https://ietresearch.onlinelibrary.wiley.com/doi/10.1049/iet-cdt.2019.0027 | |
dc.title | Ultra-low power digital front-end for single lead ECG acquisition integrated with a time-to-digital converter | |
dspace.entity.type | Publication | |
relation.isAuthorOfPublication | a0d02c67-380f-4408-bf67-20c265f67093 | |
relation.isAuthorOfPublication | a0d02c67-380f-4408-bf67-20c265f67093 | |
relation.isAuthorOfPublication.latestForDiscovery | a0d02c67-380f-4408-bf67-20c265f67093 |