Show simple item record

dc.contributor.advisorMishra, Biswajit
dc.contributor.authorGandhi, Samkit Rakeshbhai
dc.date.accessioned2019-03-19T09:30:52Z
dc.date.available2019-03-19T09:30:52Z
dc.date.issued2018
dc.identifier.citationGandhi, Samkit Rakeshbhai (2018). Design Consideration for a Novel BatchingControl Unit on an FPGA. Dhirubhai Ambani Institute of Information and Communication Technology, viii, 61 p. (Acc. No: T00705)
dc.identifier.urihttp://drsr.daiict.ac.in//handle/123456789/739
dc.description.abstractIn a concrete plant, the batch plant controls are needed to control and monitorthe amount of ingredients to be mixed to form concrete. This report presents designconsiderations for a novel batch mix controller. In the proposed architecture atime based analog to digital converter (ADC) is implemented. The weighing erroris only 0.4%. The proposed architecture has a higher sampling frequency of 400Hzfor a single channel.For four channels sampling frequency achieved is 100Hz foreach channel. As batch mix controller is placed at remote place a wireless communicationfacility is provided using GSM modem. Input protection circuit is usedto protect the hardware from overvoltage, overcurrent and reverse voltage. Thehardware disconnects from the power supply when current in the hardware increasesabove 2.25A (up to 100A), when supply voltage's polarity is reversed (upto 80V), when supply voltage increases above 15.6V (up to 500V).
dc.publisherDhirubhai Ambani Institute of Information and Communication Technology
dc.subjectAnalog to digital converter
dc.subjectGSM
dc.subjectReverse voltage
dc.subjectOvercurrent
dc.classification.ddc621.38215 GAN
dc.titleDesign consideration for a novel batching control unit on an FPGA
dc.typeDissertation
dc.degreeM. Tech
dc.student.id201611011
dc.accession.numberT00705


Files in this item

Thumbnail

This item appears in the following Collection(s)

Show simple item record